Cable cover

Fan B3

Fan B2

Connector for fan B3

Connector for fan B1

Connector for fan B2

Fan B1

Figure 7.25 Cooling Fan Wiring: 2A0360, 2A0415, 4A0250 to 4A0362, 5A0192, and 5A0242

4.

Double-check the relay connector to ensure it is properly connected.

5.

Reattach the cable cover to its original position and tighten the screws so the fan guard holds the cable cover in place.

Note:

Do not pinch the fan cable between parts when reassembling the fan unit.

n

Installing the Cooling Fan Unit

1.

Reverse the procedure described above to reinstall the cooling fan unit.

Figure 7.26 Install the Cooling Fan Unit: 2A0169 to 2A0415 and 4A0139 to 4A0362, and 5A0062 to 5A0242

2.

Reattach the covers and digital operator.

3.

Turn on the power supply and set o4-03 to 0 to reset the Maintenance Monitor cooling fan operation time.

7.4 Drive Cooling Fans

358

YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual

This manual is related to the following products: