Setting 12: Timer Output

This setting configures a digital output terminal as the output for the timer function.

Refer to b4: Delay Timers on page 159

for details.

Setting 13: Speed Agree 2 (f

ref

/f

out

Agree 2)

The output closes when the actual output frequency is within the speed agree width (L4-04) of the current frequency reference,

regardless of the direction.

Status

Description

Open

Output frequency or motor speed does not match the frequency reference while the drive is running.

Closed

Output frequency or motor speed is within the range of frequency reference ±L4-04.

Note:

Detection works in forward and reverse.

L4-04

L4-04

Frequency
reference

Speed Agree 2

ON

OFF

Output Frequency

or Motor Speed

Figure 5.51 Speed Agree 2 Time Chart

Refer to L4-03, L4-04: Speed Agreement Detection Level and Detection Width (+/-) on page 252

for more details.

Setting 14: User-Set Speed Agree 2 (f

ref

/f

set

Agree 2)

The output closes when the actual output frequency and the frequency reference are within the speed agree width (L4-04) of

the programmed speed agree level (L4-03).

Status

Description

Open

Output frequency or motor speed and frequency reference are both outside the range of L4-03 ±L4-04.

Closed

Output frequency or motor speed and the frequency reference are both within the range of L4-03 ±L4-04.

Note:

The detection level L4-03 is a signed value; detection works in the specified direction only.

Frequency reference

+

L4-04

Frequency reference – L4-04

L4-03

L4-03

+

L4-04

L4-03 – L4-04

Frequency
reference

0 Hz

OFF

OFF

ON

ON

Frequency reference

During

Forward

Output frequency

Output frequency

User Set
Speed Agree 2

Figure 5.52 User-Set Speed Agree 2 Example with a Positive L3-04 Value

Refer to L4-03, L4-04: Speed Agreement Detection Level and Detection Width (+/-) on page 252