beautypg.com

Yaskawa AC Drive-P1000 Industrial Fan User Manual

Page 357

background image

2A0169, 2A0211, 4A0139
5A0062, 5A0077, 5A0099

4A0165

Connector for fan B1

Fan B1

Fan B2

Connector for fan B2

Figure 7.23 Cooling Fan Wiring: 2A0169, 2A0211, 4A0139, 4A0165, and 5A0062 to 5A0099

3.

Make sure that the protective tube does not stick out beyond the fan guard.

n

Cooling Fan Wiring: 2A0250, 2A0312, 4A0208, 5A0125, and 5A0145

1.

Position the protective tube so the fan connector sits in the center of the protective tube.

Protective tube

2.

Insert the connector for fan B2 and guide the lead wire for fan B2 so the cable hook holds it in place.
Insert the connector for fan B1.

Cable hook

Connector for fan B2

Connector for fan B1

Fan B2

Fan B1

Figure 7.24 Cooling Fan Wiring: 2A0250, 2A0312, 4A0208, 5A0125, and 5A0145

3.

Make sure that the protective tube does not stick out beyond the fan guard.

n

Cooling Fan Wiring: 2A0360, 2A0415, 4A0250 to 4A0362, 5A0192, and 5A0242

1.

Position the protective tube so the fan connector sits in the center of the protective tube.

Protective tube

2.

In the space between fans 1 and 2, place the fan connector for fan B2 in front of the fan connector for fan B1.

3.

Place the connector for fan B3 between fans B2 and B3.

7.4 Drive Cooling Fans