Yaskawa MP920 User's Manual Design User Manual
Page 557

Appendix A
A-42
A.6
Connection between
Σ-II Series SERVOPACKs and MP920
Modules
The following conditions must be satisfied to connect
Σ-II series SERVOPACKs and the MP920
Modules.
Software Version Number
MP920 Fixed Parameters
SVA-01A and SVA-02A Modules
SVB-01 Module
MP920 Modules and MPE720
Version No.
MPE720
Ver.3.10 or later
MP920
SVA-01A
A08 or later
SVA-02A
A05 or later
SVB-01
A05 or later
CPU-01
A07 or later
No.
Name
Setting
Description
14
Additional
Function
Selection
Bit 9
Σ-II series
Servopack
selection
1
Set this bit to 1 to enable the processing for
Σ-II series
SERVOPACK.
0: Use
Σ-I series SERVOPACK.
1: Use
Σ-II series SERVOPACK.
Bits 12
to 15
Error detection
coefficient
0
(default)
Change the setting if a position error occurs when using a
high-resolution encoder.
Position error will be checked by comparing the position
with the value of the setting parameter OW
0F (Error
Count Alarm Detection Setting) mutiplied by 2
n
(n: Error
detection coefficient).
No.
Name
Setting
Description
9
Number of Feedvack Pulses per
Rotation (For High-resolution)
(No. of
encoder
pulses)
Set the number of encoder pulses before multiplication.
14
Additional
Function
Selection
bit 9
Number of
encoder pulses
setting selection
1
Set this bit to 1 to enable the fixed parameter No. 9.
0: Enables the fixed parameter No. 8.
1: Enables the fixed parameter No. 9.