Yaskawa MP920 User's Manual Design User Manual
Page 529

Appendix A
A.2.1 Ladder Instruction List
A-14
Relay Circuit
Instruction
NO CONTACT
No limit in a series circuit.
Bit designation of any register as a relay number is possible.
NC CONTACT
No limit in a series circuit.
Bit designation of any register as a relay number is possible.
RISING PULSE
No limit in a series circuit.
Bit designation of any register as a relay number is possible.
FALLING PULSE
No limit in a series circuit.
Bit designation of any register as a relay number is possible.
10-MS ON-DELAY
TIMER
Set value: Timer register
Set value = any register or constant (setting unit: 10 ms)
Timer register = M or L register
10-MS OFF-
DELAY TIMER
1-S ON-DELAY
TIMER
Set value: Timer register
Set value = any register or constant (set ting unit: 10 ms)
Timer register = M or L register
1-S OFF-DELAY
TIMER
COIL
SET COIL
RESET COIL
Branching/
convergence
A branching or convergence symbol can be connected to any
of the above relay instructions.
Logic
Operation
Instructions
AND
V
Integer designation of any register or constant is possible.
OR
V
Integer designation of any register or constant is possible.
XOR
Integer designation of any register or constant is possible.
Numeric
Operation
Instructions
ADDITION +
Ordinary numeric addition (with operation error)
SUBTRACTION -
Ordinary numeric subtraction (with operation error)
EXTENDED
ADDITION
++
Closed numeric addition (without operation error)
0
→ 32767 → -32768 → 0
EXTENDED
SUBTRACTION
- -
Closed numeric subtraction (without operation error)
0
→ -32768 → 32767 → 0
INTEGER ENTRY
Starts an integer operation.
REAL NUMBER
ENTRY
Starts a real number operation.
(cont’d)
Type
Name
Symbol
Description
T
T
T
S
S
S
MW0200 = 0001
MB000000
MB000000
IFON
S
MB000010
MB000000
S
R
MB000010
MB000020
R
MW00280 +
00100
MW00220
MW00280 -
00100
MW00220
MW00280 +
00100
MW00220
MF00280 + 1.000000E + 002
MF00220