5.3 I/O Modules

5-51

5

Connection to a Pulse Generator with 5-V Differential Output

An example of connection to a pulse generator with 5-V differential output is shown below.

• Use the cable model JEPMC-W6060-†† for connection between the CNTR-01 Module and the

junction terminals.

• Use the following cable for connection between the junction terminal block and the pulse genera-

tor.

• Shielded twisted-pair cable
• Do not connect anything to the unused input terminals.

0V

75ALS1177

+5PA1

L

2.2k

2.2k

2.2k

2.2k

47k

47k

47k

47k

47k

47k

-5PA1

+5PB1

-5PB1

EN

PIASEL

Vb

75ALS1177

+5PC1

-5PC1

EN

PIASEL

GND

CN1

CNTR-01

+5V

L

L

L

2.2k

L

2.2k

L

330

330

330

Pulse generator

Phase A

Phase B

Phase C

Junction terminal block

(Connector shell)

INFO