Yaskawa MP920 User's Manual Design User Manual
Page 216

5.3 I/O Modules
5-21
5
The following table shows the name and function of the CN2 connector pins.
Pin
No.
Signal
Name
Function
Pin
No.
Signal
Name
Function
1
COM-5
Common 5
26
2
DI-32
Digital input 32
(also used as interrupt input)
27
DI-33
Digital input 33
(also used as interrupt input)
3
DI-34
Digital input 34
28
DI-35
Digital input 35
4
DI-36
Digital input 36
29
DI-37
Digital input 37
5
DI-38
Digital input 38
30
DI-39
Digital input 39
6
31
7
COM-6
Common 6
32
8
DI-40
Digital input 40
33
DI-41
Digital input 41
9
DI-42
Digital input 42
34
DI-43
Digital input 43
10
DI-44
Digital input 44
35
DI-45
Digital input 45
11
DI-46
Digital input 46
36
DI-47
Digital input 47
12
37
13
COM-7
Common 7
38
14
DI-48
Digital input 48
39
DI-49
Digital input 49
15
DI-50
Digital input 50
40
DI-51
Digital input 51
16
DI-52
Digital input 52
41
DI-53
Digital input 53
17
DI-54
Digital input 54
42
DI-55
Digital input 55
18
43
19
COM-8
Common 8
44
20
DI-56
Digital input 56
45
DI-57
Digital input 57
21
DI-58
Digital input 58
46
DI-59
Digital input 59
22
DI-60
Digital input 60
47
DI-61
Digital input 61
23
DI-62
Digital input 62
48
DI-63
Digital input 63
24
49
25
50
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)