Yaskawa MP920 User's Manual Design User Manual
Page 403

7 Parameters
7.2.1 Motion Fixed Parameters
7-8
21
Servomotor Gear
Ratio
(GEAR_MOTOR)
1 to 65535
(Default = 1)
1 = 1 rev (rotation)
√
√
√
√
22
Machine Gear Ra-
tio
(GEAR_
MACHINE)
1 to 65535
(Default = 1)
1 = 1 rev (rotation)
√
√
√
√
23
Infinite Length
Axis Reset Posi-
tion (POSMAX)
1 to 2
31
-1
(Default = 360000)
1 = 1 reference unit
√
√
√
√
25
Maximum Num-
ber of Absolute
Encoder Turns
(MAXTURN)
1 to 2
31
-1
(Default = 99999)
1 = 1 rev (rotation)
√
√
√
27
Positive Software
Limit (SLIMP)
-2
31
to 2
31
-1
(Default = 2
31
-1)
1 = 1 reference unit
√
√
√
√
29
Negative Soft-
ware Limit
(SLIMN)
-2
31
to 2
31
-1
(Default = 2
31
-1)
1 = 1 reference unit
√
√
√
√
31
Zero Point Return
Method
(ZRETSEL)
0 to 7
(Default = 0)
0: DEC1 + C-phase pulse
√
√
√
1: ZERO
√
√
2: DEC1 + ZERO
√
√
√
3: C-phase pulse
√
√
√
4: DEC2 + ZERO
√
√
5: DEC1 + LMT + ZERO
√
√
6: DEC2 + C-phase pulse
√
√
7: DEC1 + LMT + C-phase pulse
√
√
32
Backlash Com-
pensation
(BKLSH)
0 to 32767
(Default = 0)
1 = 1 reference unit
√
√
33
Number of Feed-
back Pulses per
Rotation (For
Simulation)
1 to 2
31
-1
(Default = 200)
1 = 1 pulse
Number of pulses per
stepping motor rotation
√
35
Bias Speed
(BIASSPD)
0 to 32767
(Default = 0)
1 = 10
n
reference units/min (n = Number of digits below
decimal point)
Pulse units: 1 = 1,000 pulses/min.
mm units: 1 = 1 mm/min
deg units: 1 = 1 deg/min
inch units: 1 = 1 inch/min
√
36
Bias Speed for the
Exponential Accel-
eration/Decelera-
tion Filter
(EXPBIAS)
0 to 32767
(Default = 0)
1 = 10
n
reference units/min (n: Number of digits below
decimal point)
Pulse units: 1 = 1,000 pulses/min
mm units: 1 = 1 mm/min
deg units: 1 = 1 deg/min
inch units: 1 = 1 inch/min
√
√
√
Table 7.2 Motion Fixed Parameters (cont’d)
No.
Name
Setting Range
Meaning
Remarks
SVA
-01A
SVA
-02A
SVB
-01
PO
-01