beautypg.com

Yaskawa MP920 User's Manual Design User Manual

Page 399

background image

7 Parameters

7.1.2 Module Numbers and Motion Parameter Register Numbers

7-4

Axis offset = (axis number - 1)

× 40H (64 words)

This yields the following servo parameter register numbers.

Register numbers will not be consecutive across registers for different Module numbers, but will be
consecutive among axes for the same Module number. Therefore, special attention must be paid when
using superscripts (I, J) in user programs.

Example:

I = 0 to 255 can be read using

IW(OW) C000i.

IW(OW) C000 reads the registers for Module number 1, that is in the range from IW(OW) C000 to
IW(OW) C0FF. It will not read correctly beyond I > 256.

Table 7.1 Motion Parameter Register Numbers

Module No.

Axis 1 IW(OW)

Axis 2 IW(OW)

Axis 3 IW(OW)

Axis 4 IW(OW)

1

C000 to C03F

C040 to C07F

C080 to C0BF

C0C0 to C0FF

2

C400 to C43F

C440 to C47F

C480 to C4BF

C4C0 to C4FF

3

C800 to C83F

C840 to C87F

C880 to C8BF

C8C0 to C8FF

4

CC00 to CC3F

CC40 to CC7F

CC80 to CCBF

CCC0 to CCFF

5

D000 to D03F

D040 to D07F

D080 to D0BF

D0C0 to D0FF

6

D400 to D43F

D440 to D47F

D480 to D4BF

D4C0 to D4FF

7

D800 to D83F

D840 to D87F

D880 to D8BF

D8C0 to D8FF

8

DC00 to DC3F

DC40 to DC7F

DC80 to DCBF

DCC0 to DCFF

9

E000 to E03F

E040 to E07F

E080 to E0BF

E0C0 to E0FF

10

E400 to E43F

E440 to E47F

E480 to E4BF

E4C0 to E4FF

11

E800 to E83F

E840 to E87F

E880 to E8BF

E8C0 to E8FF

12

EC00 to EC3F

EC40 to EC7F

EC80 to ECBF

ECC0 to ECFF

13

F000 to F03F

F040 to F07F

F080 to F0BF

F0C0 to F0FF

14

F400 to F43F

F440 to F47F

F480 to F4BF

F4C0 to F4FF

15

F800 to F83F

F840 to F87F

F880 to F8BF

F8C0 to F8FF

16

FC00 to FC3F

FC40 to FC7F

FC80 to FCBF

FCC0 to FCFF

IMPORTANT