Chapter 4: Starting a Management Session

98

b. From the Main Menu, select Administration.

c. From the Administration Menu, select Event Log and Display

Event Log. If the AT-CV1203 Chassis has just one power supply
or if it has two power supplies but not a management card, you
should see this message in the event log:

Dying Gasp has occurred on remote linecard

number

.

Number is the slot number of the line card in the AT-CV5000

Chassis that received the dying gasp signal from its remote
counterpart line card in the AT-CV1203 Chassis.

If the remote AT-CV1203 Chassis has two power supplies and the

AT-CV5M02 Management Card, the event log should also contain
this message, logged when the first power supply on the remote
chassis lost power.

CV1203 RPS Failure on Remote Line Card

number

The number variable performs the same function in this message
as it does in the previous message, indicating the slot number of
the line card that received the signal in the AT-CV5000 Chassis.