Converteon Management Software User’s Guide

245

4. From the TDM Management Menu, select UART Configurations to

display the UART Configuration Menu, shown in Figure 100.

Figure 100. UART Configuration Menu

5. From the UART Configuration Menu, select one of the following

options:

ˆ

UART Local Console Mode - This setting lets you configure the T1/
E1 ports from the Console port on the line card. This is the
appropriate setting if the line card will be installed in a chassis that
does not have the AT-CV5M02 Management Card. This is the
default setting.

ˆ

UART Back Plane Mode - This setting lets you configure the T1/E1
ports through the AT-CV5M02 Management Card. This is the
appropriate setting if the line card will be installed in a chassis that
has the management card.

6. At the confirmation prompt, type Y to implement your change or type N

to cancel it.

7. Wait one minute for the line card to reset and initialize its management

software.

8. If you set the line card to the UART Local Console Mode to deploy the

card at a remote site, remove the line card from the chassis.

9. If you set the line card to the UART Back Plane Mode so that you can

use the AT-CV5M02 Management Card to configure its parameter
settings, go to the next procedure for instructions.

UART Configuration Menu

Module 15, Port C

> UART Local Console Mode

UART Back Plane Mode

Return to Port Configuration Menu ...