Restoring the last saved configuration – Allied Telesis AT-S102 User Manual
Page 226
Chapter 7: Configuring the Media Converter Line Cards with Remote Peer Management
226
2. To view the default settings of the line card prior to activating them,
select Display Default Configuration. An example of the Display
Default Configuration window is shown in Figure 80 on page 192.
3. To return the parameter settings on the line card to the default values,
return to the Line Card Configuration Menu and select Return Line
Card to Default Configuration.
4. At the confirmation prompt, select Yes to return the parameter settings
on the line card to the default values or No to cancel the procedure.
5. If the card changes its operating mode, it resets. To continue
managing the line card, return to the Main Menu and wait one to two
minutes for the card to initialize its management software and to
negotiate the OAM settings with its local counterpart. Then select the
card again from the Remote Module Status and Configuration
menu.
Restoring the
Last Saved
Configuration
This procedure is used to restore a remote line card to the last saved
configuration stored in the master configuration file on the management
card in the local chassis. This procedure can be used to discard any
parameter changes that you may have made to a line card but did not
save in the master configuration file, or to assign to a new remote line card
the save settings as its predecessor. For more information, refer to
“Configuration Files” on page 32.
Caution
If the card’s current operating mode is different from its last saved
configuration, the card will reset, possibly resulting in the loss of
some network traffic. As the line card initializes its management
software, which takes approximately one minute, it forwards traffic
using its default parameter settings.
To use the menus to restore the last saved configuration to a line card:
1. From the Remote Module Configuration Menu, select Line Card
Configuration.
2. To view the parameter settings of the card’s last saved configuration
before activating them on the line card, select Display Last Saved
Configuration. If the fields are empty, the master configuration file
does not have a previous configuration for this slot or the previous and
current line cards of the slot are different models.
3. To return the line card to its last saved configuration, return to the Line
Card Configuration menu and select Restore Last Saved
Configuration.
4. At the confirmation prompt, select Yes to restore the settings or No to
cancel the procedure.