Figure 99. uart settings on the at-cm70s line card – Allied Telesis AT-S102 User Manual
Page 243
Converteon Management Software User’s Guide
243
Figure 98 illustrates the idea of the UART setting. It shows a deployment
of two AT-CM70S Line Cards and their UART settings. The UART setting
of the line card in the AT-CV5000 Chassis is set to UART backplane mode
so that the T1/E1 ports on the card can be managed through the
management card in the chassis. In contrast, the UART setting of the card
at the remote site is set to UART console mode so that the T1/E1 ports
can be managed through the card’s Console port at the site. If the card at
the remote site had a UART setting of UART backplane mode, you would
have to remove the card from the chassis and install it into another unit
that had a management card whenever you wanted to configure the T1/E1
ports.
Figure 98. UART Settings on the AT-CM70S Line Card
Here are the general steps to configuring a pair of AT-CM70S Line Cards:
1. For the initial configuration, install both of the AT-CM70S Line Cards in
an AT-CV5000 Chassis that has the AT-CV5M02 Management Card.
2. Using the menus interface in the management card, change the UART
setting on both cards to UART backplane mode so that you can
configure all of the parameter settings, including the T1/E1 ports, using
the management card.
AT-CV1200
FAN1
PS1
RDY
A
T
-CV5000
AT-CV1203 Chassis
AT-CV5000 Chassis
with a Management
Card
AT-CM70S Line Card Set
to the UART Backplane
Mode
AT-CM70S Line Card Set
to the UART Local
Console Mode