Figure 99. uart settings on the at-cm70s line card – Allied Telesis AT-S102 User Manual

Page 243

background image

Converteon Management Software User’s Guide

243

Figure 98 illustrates the idea of the UART setting. It shows a deployment
of two AT-CM70S Line Cards and their UART settings. The UART setting
of the line card in the AT-CV5000 Chassis is set to UART backplane mode
so that the T1/E1 ports on the card can be managed through the
management card in the chassis. In contrast, the UART setting of the card
at the remote site is set to UART console mode so that the T1/E1 ports
can be managed through the card’s Console port at the site. If the card at
the remote site had a UART setting of UART backplane mode, you would
have to remove the card from the chassis and install it into another unit
that had a management card whenever you wanted to configure the T1/E1
ports.

Figure 98. UART Settings on the AT-CM70S Line Card

Here are the general steps to configuring a pair of AT-CM70S Line Cards:

1. For the initial configuration, install both of the AT-CM70S Line Cards in

an AT-CV5000 Chassis that has the AT-CV5M02 Management Card.

2. Using the menus interface in the management card, change the UART

setting on both cards to UART backplane mode so that you can
configure all of the parameter settings, including the T1/E1 ports, using
the management card.

AT-CV1200

FAN1

PS1

RDY

A

T

-CV5000

AT-CV1203 Chassis

AT-CV5000 Chassis

with a Management

Card

AT-CM70S Line Card Set

to the UART Backplane

Mode

AT-CM70S Line Card Set

to the UART Local

Console Mode