Chapter 4: Starting a Management Session

72

Starting a Local Management Session

This procedure explains how to start a local, out-of-band management
session using the RS-232 Console port on the AT-CV5M02 Management
Card. The management card does not need an IP address for local
management. Your initial management session has to be a local session.

The Console port on the management card requires a DEC VT100 or
ANSI terminal, or an equivalent terminal emulator program, capable of
displaying up to 125 characters per line.

To start a local management session:

1. Connect one end of the management cable included with the

management card to the Console port on the management card, as
shown in Figure 11. If the chassis has two AT-CV5M02 Management
Cards, start the session on the active management card, identified by
its green RDY LED.

Figure 11. Connecting the Management Cable to the Management Card’s

Console Port

2. Connect the other end of the cable to an RS-232 port on a terminal or

a PC with a terminal emulator program.

3. Configure the terminal or the terminal emulation program as follows:

ˆ

Bits per second: 115200 default (range 2400 to 115200 bps)

ˆ

Data bits: 8

ˆ

Parity: None

ˆ

Stop bits: 1

ˆ

Flow control: None