Menus, Figure 84. local cm line card diagnostics menu – Allied Telesis AT-S102 User Manual
Page 199
Converteon Management Software User’s Guide
199
Resetting All of the AT-CM2, AT-CM3, and AT-CM70S Media
Converter Line Cards
The procedures in this section are used to reset all of the AT-CM2,
AT-CM3, and AT-CM70S Line Cards in a chassis.
Caution
Resetting an AT-CM Line Card disrupts its normal operations. Some
network traffic may be lost. When an AT-CM Line Card is reset, it
has to initialize its management software. During the initialization
process, which takes approximately one minute, the line card
forwards network traffic using the default values for its parameter
settings. Afterwards, it configures its parameters using the settings
from the AT-CV5M02 Management Card or from its own
configuration file, depending on the auto-copy setting of its slot.
This procedure does not affect AT-CV Line Cards or the AT-CV5M02
Management Card. To reset the AT-CV Line Cards, refer to “Resetting All
of the AT-CM, AT-CM70S, and AT-CV Media Converter Line Cards” on
page 201. For instructions on how to reset the AT-CV5M02 Management
Card, refer to “Resetting the Management Card” on page 119.
Menus
To reset all of the AT-CM2, AT-CM3, and AT-CM70S Line Cards in the
chassis from the menus:
1. From the Main Menu, select Diagnostics. The Diagnostics Menu is
shown in Figure 53 on page 148.
2. From the Diagnostics Menu, select Local CM Line Card Diagnostics
Menu to display the menu in Figure 83.
Figure 83. Local CM Line Card Diagnostics Menu
3. Select Reset All CM Line Cards.
Local CM Line Card Diagnostics Menu
Converteon
Image Version
MAC Address and Serial Number
SFP Information
Reset All CM Line Cards
Return to Diagnostics Menu...