Chapter 8: Configuring the T1/E1 Ports on the AT-CM70S Media Converter Line Card

250

Figure 104. Local Console Menu on the AT-CM70S Line Card

The first selection in the menu, Boot Data From, returns the
parameter settings of the T1/E1 ports to the default values. This
selection initially says Manufacture Default, indicating that the
parameter settings on the ports are at their default values. As you
configure the ports, it automatically changes to Customized in
EEPROM. If at a later time you want to discard all of your changes and
return the ports to the default values, type a (lowercase) and respond
to the confirmation prompt.

The second selection, LIU Mode, toggles the line card between T1
or E1 support, as explained in step 4.

The main part of the menu is a table that displays the current settings
of the T1/E1 ports (channels). To change a setting of a port, refer to
step 5.

4. To toggle the line card between T1 or E1 support:

Note

Changing the T1/E1 mode of the line card returns the port settings to
the default values. Any changes to the port settings are discarded.

a. Type b (lowercase) to select LIU Mode and press Return.

AT-CM70S Local Console Menu

--------------------------------------------------------------------

Boot Configuration:
Boot Data From

: Customized in EEPROM

LIU Mode

: T1

--------------------------------------------------------------------

Current Status:
T1 with B8ZS Coding (All 4 Channels)

Channel 1

Channel 2

Channel 3

Channel 4

<1> Rec Sens Set

: Long Haul

Long Haul

Long Haul

Long Haul

<2> Line Build Out

: DSX-1/0 CSU DSX-1/0 CSU DSX-1/0 CSU DSX-1/0 CSU

<3> Transmit All 1s : Normal

Normal

Normal

Normal

<4> PRBS

: Disabled

Disabled

Disabled

Disabled

<5> Remote Loopback : Disabled

Disabled

Disabled

Disabled

Enter to change each channel's config.

Change will be saved automatically if EEPROM data was used.

Command>