Chapter 5: Configuring the AT-CV5M02 Management Card

154

Web Browser

This management function is not supported in the web browser windows.

LI

This column displays the time interval (in seconds)
between the polling of the previous line card and the
polling of the current line card by the management card.

CI

This column displays the time interval (in seconds)
between the end of one complete polling cycle and the
start of the next cycle. A cycle ends when the
management card polls the line card in the highest
numbered slot in the chassis and begins when it polls the
card in the lowest numbered slot.

CY

This column displays the time interval (in seconds) since
the start of the current polling cycle. A cycle starts when
the management card polls the line card in the lowest
numbed slot in the chassis.

LC

This column displays the time interval (in seconds) since
a line card was polled.

IPC

This column displays the time interval (in seconds) the
management card waited for the IPC response from a
line card.

NMSG

This column displays the number of messages the
management card has in its queue.

NBUF

This column displays the number of messages stored in
the buffer on the management card.

Table 18. IPC Message