125
CV1203 Local RPS
Failure A/B
AT-CV1203
Report
One of the two external power supplies
connected to the AT-CV1203 Chassis
failed. (A failed power supply has no
detectable output voltages.) “A” and “B”
designate the power connectors on the
back panel of the chassis. This message
only appears if the AT-CV1203 Chassis
has two power supplies and just one of
the power supplies fails.
Clear
A power supply connected to the
AT-CV1203 Chassis resumed normal
operations or was replaced.
CV1203 RPS Failure
on Remote Line Card
n
AT-CV1203
AT-CV5000
Report
The media converter line card in slot n of
the AT-CV5000 Chassis received a report
from its line card counterpart in a remote
AT-CV1203 Chassis that one of the two
power supplies connected to the remote
chassis lost power. This message
requires remote peer management. For
background information, refer to “Dying
Gasp and First RPS Failure Signals” on
page 62. For instructions on how to
configure the line cards for this feature,
refer to “Configuring the AT-CM2,
AT-CM3, and AT-CM70S Line Cards for
the OAM-based Features” on page 90.
If a remote AT-CV1203 Chassis loses all
power and has at least one AT-CM Media
Converter Line Card, it sends the dying
gasp signal instead of this signal.
Clear
The media converter line card in slot n of
the AT-CV5000 Chassis received a clear
signal from its line card counterpart in a
remote AT-CV1203 Chassis, indicating
that power has been restored. This
message requires remote peer
management.
Table 13. General Event Messages