First RPS Failure

The AT-CM Line Cards send this signal if the AT-CV1203 Chassis has
both a primary power supply and a redundant power supply, and just one
of the power supplies loses power. The signal indicates that the remote
chassis is continuing to operate after having lost power on one of its power
modules.

The following subsections explain how this feature works on the AT-CM2
and AT-CM3 Line Cards.

Table 7. Versions of the AT-CM2 Line Cards that Support Dying Gasp

Media Converter Line Card

Hardware Version

AT-CM201

Version 2

AT-CM202

Version 2

AT-CM202/1

Version 2

AT-CM202/2

Version 2

AT-CM212A/1

Version 2

AT-CM212B/1

Version 2

AT-CM70S

Version 2

AT-CM2K0S

Version 3

Table 8. Versions of the Management Software that Support Dying Gasp

Management and Media

Converter Line Cards

Management Software Versions

AT-CV5M01 Management Card

Version 2.0.2 or later of the
AT-S70 Management Software.

AT-CV5M02 Management Card

Version 3.0.0 or later of the
AT-S99 Management Software

AT-CM2 Line Cards

Version 2.0.2 or later of the
AT-S73 Line Card Management
Software.

AT-CM3 Line Cards

Version 3.0.0 or later of the
AT-S102 Line Card Management
Software.