beautypg.com

Allied Telesis AT-S102 User Manual

Page 249

background image

Converteon Management Software User’s Guide

249

Configuring the T1/E1 Ports from the Console Port on the Line Card

This procedure explains how to configure the settings on the T1/E1 ports
on the AT-CM70S Line Card from the card’s Console port. This is the
appropriate procedure for configuring the ports when the card’s UART
setting is set to UART local console mode and the chassis containing the
line card does not have a management card.

Caution

There are no security features like a logon username or a password
on the Console port on the AT-CM70S Line Card. Anyone with
physical access to the location of the card can alter the configuration
settings of the T1/E1 ports. To prevent unauthorized changes to its
operating parameters, install the card and its chassis in a secure
location, such as a locked wiring closet.

Note

The parameter settings of the SFP slot and the 10/100/1000Base-T
port on the line card cannot be set through the Console port.

To configure the T1/E1 ports from the Console port on the AT-CM70S Line
Card:

1. Configure the settings on your terminal or terminal emulator program

as follows:

ˆ

Bits per second: 115200

ˆ

Data bits: 8

ˆ

Parity: None

ˆ

Stop bits: 1

ˆ

Flow control: None

ˆ

Echo typed characters locally: Enabled

Note

The settings on the Console port on the line card are not adjustable.

2. Connect the management cable included with the AT-CM70S Line

Card to the Console port on the card and to the RS-232 port on your
terminal or computer.

3. If the card is already running, the terminal screen will be blank. To

display the card’s menu in Figure 104, type m for menu and press
Return.

This manual is related to the following products: