Web browser – Allied Telesis AT-S102 User Manual
Page 113
Converteon Management Software User’s Guide
113
6. To save your changes in the master configuration file, return to the
System Configuration Menu and select Save System Configurations.
Web Browser
To configure the security features of the management software from the
web browser windows:
1. Select Configuration from the left menu bar.
2. If the System tab is not selected, select it. The System tab is shown in
3. To configure the security features, click the Edit button in the Omega
Options section of the tab to display a pop-up window.
4. Configure the parameters as needed. The options are defined in Table
11, “Omega Options Menu” on page 112.
5. Click the Update button.
6. To save your changes in the master configuration file, click the Edit
button in the Configuration section of the window and select the Save
System Configuration option.
Local Omega Enabled
Disable Local Omega
These parameters are used to enable or disable the Console
port on the management card. When the Console port is
disabled, local management of the chassis through the RS-
232 Console port is prohibited. The default setting for the
Console port is enabled.
If you disable local management during a local management
session, your current session is not interrupted. However,
the card will not allow you to establish any new local
management sessions.
When disabled, the Console port still displays bootup
information when the card is powered on.
Remote Omega Enabled
No Remote Omega
These parameters are used to enable and disable the Telnet
server on the management card. The default setting is
enabled. When this option is set to disabled, you cannot
manage the chassis from a remote Telnet client.
Note
To set the web browser server, refer to “Enabling or
Disabling the Web Server” on page 114.
Table 11. Omega Options Menu
Parameter
Description