Functional Description

ARTM-831X Installation and Use (6806800M76E)

91

The HEALTH signal is buffered by a high current driver and directly routed to the line interface
connectors on the face plate.

The PRI_SBY signal is buffered by a high current driver and directly routed to the line interface
connectors on the face plate.

Additionally this signal is connected to the RxSEL (E1/T1 Framer only) and TxON signals of the
framer devices to allow dedicated control of line termination and Transmitter status.

4.4.5.1

Locate and type detect function (patch panel)

For the connections to the patch panel a "locate" and a "type detect" function are available.
These functions are enabled through an "ID_PRSNT" analog signal which is present individually
on each VHDCI interface connector at the face plate.

The ID_PRSNT signals are pulled to a local voltage source, routed via the mezzanine connector
to the IPMC on the base ARTM and connected to the integrated multi-channel ADC. The IPMC
samples the signal and provides the status and LED drive signal as described below (see also
chap. 3.7.1 on IPMI building block implementation).

PRI_SBY

Purpose is to indicate if blade is primary or standby
Vhigh max = +5V
Vhigh min = +4.5V
Vlow max = +0.2V
I max = 500mA
Set HIGH to indicate one blade is primary
Set LOW to indicate the other blade is primary