beautypg.com

1 sfp overhead signals, 2 essi signals, 7 on board resources (ipmi) – Artesyn ARTM-831X Installation and Use (June 2014) User Manual

Page 71: 1 sfp overhead signals 4.2.6.2 essi signals, Essi signals

background image

Functional Description

ARTM-831X Installation and Use (6806800M76E)

71

4.2.6.1

SFP Overhead Signals

The SFP overhead signals are routed to the FPGA_base device:

SFP+ I2C control (FPGA I/O)

Loss of signal (FPGA input, also routed to the Framer device)

Transmitter disable (FPGA I/O)

SFP present (FPGA input)

4.2.6.2

ESSI Signals

Both ESSI (per Framer) are routed via the mezzanine connector to the Zone 3 connector in
order to support APS for SONET signals. For details, see

ESSI Interface and Routing

on page 89

.

On the E1/T1 only variant of the ARTM-831X assembly the same physical lines are partly used
to route the 166.7Hz multi-frame sync clock. For details, see

ESF Sync 166Hz Routing

on page 81

4.2.7

On Board Resources (IPMI)

IPMI support on ARTM-831X is implemented by using the IPMI building block based on the
AMC Pigeon Point Reference Design. This building block is based on the 8-bit micro-controller
family AVR from Atmel, type ATmega128L.