Sensor data records, 1 sensor data records, Table 7-1 – Artesyn ARTM-831X Installation and Use (June 2014) User Manual
Page 109: Sensor data records 7.1 sensor data records

Sensor Data Records
ARTM-831X Installation and Use (6806800M76E)
109
Sensor Data Records
7.1
Sensor Data Records
This section provides a description of all analog and discrete Sensors available at the ARTM-831X.
For sensor threshold definition please use the "ipmitool" found on
http://sourceforge.net/projects/ipmitool/files/ipmitool/
with the parameter "sensor".
Table 7-1 Sensor Data Records
Sensor
Number
Sensor Name
Sensor Type
Event/Readin
g Type
Event
Data
Byte 1
Event Data
Byte 2
Event Data
Byte 3
Event
Threshold/Descr
iption
Assertion
Deassertion
Rearm
58
+12V RTM
Voltage
0x02
Threshold
0x01
reading
threshold
unr uc lnr lc
Ass / Deass
Auto
59
PP #3 Volt RTM Voltage
0x02
Threshold
0x01
reading
threshold
No Thresholds
Auto
60
PP #2 Volt RTM Voltage
0x02
Threshold
0x01
reading
threshold
No Thresholds
Auto
61
PP #1 Volt RTM Voltage
0x02
Threshold
0x01
reading
threshold
No Thresholds
Auto
62
OUTLET temp
RTM
Temp
0x01
Threshold
0x01
reading
threshold
unr uc unc
Ass / Deass
Auto
63
INLET temp
RTM
Temp
0x01
Threshold
0x01
reading
threshold
unr uc unc
Ass / Deass
Auto
64
Mezz temp
RTM
Temp
0x01
Threshold
0x01
reading
threshold
unr uc unc
Ass / Deass
Auto
65
P1 HA Status
OEM
0xDB
digital
Discrete
0x03
0x0
0x1
0xFF
0xFF
0x0: State
Deasserted
0x1: State
Asserted
Ass / Deass
Auto
66
P2 HA Status
OEM
0xDB
digital
Discrete
0x03
0x0
0x1
0xFF
0xFF
0x0: State
Deasserted
0x1: State
Asserted
Ass / Deass
Auto
Asrt: Assertion Unr: Upper non-recoverable threshold Uc: Upper critical threshold Unc: Upper non-critical threshold
Deass: Deassertion Lnr: Lower non-recoverable threshold Lc: Lower critical threshold Lnc: Lower non-critical threshold