Hardware Preparation and Installation

ARTM-831X Installation and Use (6806800M76E)

40

A local ramp-up voltage tracking control is used with the individual DC/DC converters.

2.3

Installing and Removing the RTM

The RTM must be installed into a ATCA system without a zone 3 midplane.

Table 2-2 RTM Power Requirements

Voltage

Typ.

Min.

Max.

Current

VP12

12.0V

11.4V

12.6V

3 A typ / 5A max. (including mezzanines)

V3P3_IPMI

3.3V

3.201V

3.465V

0.2 A

VP5_IPMI

4.75V

5.25V

0.1A

ARTM-831X is powered by a SELV voltage (from the front board). All communication
interfaces are also considered SELV (or optical). There are no TNV voltages on the ARTMs.

If the communication interfaces are connected to TNV circuits an external CSU (Control
Service Unit) / DSU (Digital Service Unit) is required to provide adequate signal protection.

The RTM provides support for basic hot swap, that means it can be installed, removed and
replaced in a powered system. However, after the RTM is installed or replaced in a powered
system the front blade has to be rebooted so that the OS can recognize the TSI unit as a PCIe
device on the RTM.