2 rtm power specification, Table 2-1, Environmental requirements – Artesyn ARTM-831X Installation and Use (June 2014) User Manual
Page 39: Hardware preparation and installation

Hardware Preparation and Installation
ARTM-831X Installation and Use (6806800M76E)
39
2.2.2
RTM Power Specification
Power for the ARTM-831X is provided by the front board. 12V and 5V/3.3V management
power is available at Zone 3 connectors while all additional supply voltages are generated on-
board with discrete DC/DC converters. The 12V rail is also fed via the mezzanine connectors for
expansion unit supply.
The power supply control of the ARTM-831X_base unit is in parallel to the power control of the
ATCA-8310 front board via ENABLE and PWRGOOD signaling. Both signals are controlled from,
respectively signaled to the front board power control logic.
Table 2-1 Environmental Requirements
Requirement
Operating
Non-Operating
Temperature
-5 °C to +55°C
-40°C to +85°C
Airflow resistance
50m3/h @ 25 Pa
Ambient Temp. vs. Airflow
Tamb Front board RTM
25°C 25 m3/h 3 m3/h
45°C 50 m3/h 6 m3/h
55°C 50 m3/h 6 m3/h
Temp. Change
+/- 0.5°C /min
+/- 1°C /min
Rel. Humidity
5% to 95% non condensing at
+40°C
5% to 95% non condensing at +40°C
Altitude
-300 m to +3,000 m
-300 m to +13,000 m
Vibration
20 to 2000Hz
5g(RMS) random
5g(RMS) random
Shock
5 g/30 ms half sine
15 g/11 ms half sine
Free Fall
100 mm/3 axis
1,200 mm/all edges and corners (packed state)
100 mm/3 axis (unpacked)