RTM Power Specification

Power for the ARTM-831X is provided by the front board. 12V and 5V/3.3V management
power is available at Zone 3 connectors while all additional supply voltages are generated on-
board with discrete DC/DC converters. The 12V rail is also fed via the mezzanine connectors for
expansion unit supply.

The power supply control of the ARTM-831X_base unit is in parallel to the power control of the
ATCA-8310 front board via ENABLE and PWRGOOD signaling. Both signals are controlled from,
respectively signaled to the front board power control logic.

Table 2-1 Environmental Requirements

Requirement

Operating

Non-Operating

Temperature

-5 °C to +55°C

-40°C to +85°C

Airflow resistance

50m3/h @ 25 Pa

Ambient Temp. vs. Airflow

Tamb Front board RTM
25°C 25 m3/h 3 m3/h
45°C 50 m3/h 6 m3/h
55°C 50 m3/h 6 m3/h

Temp. Change

+/- 0.5°C /min

+/- 1°C /min

Rel. Humidity

5% to 95% non condensing at
+40°C

5% to 95% non condensing at +40°C

Altitude

-300 m to +3,000 m

-300 m to +13,000 m

Vibration

20 to 2000Hz

5g(RMS) random

5g(RMS) random

Shock

5 g/30 ms half sine

15 g/11 ms half sine

Free Fall

100 mm/3 axis

1,200 mm/all edges and corners (packed state)
100 mm/3 axis (unpacked)