L-force | plc designer – Lenze PLC Designer PLC Designer (R3-1) User Manual
Page 395

L-force | PLC Designer
Menu Commands sorted by Categories
DMS 4.1 EN 03/2011 TD29
393
If there is already an object with the same name, you will be asked in a dialog, what to
do:
• Rename the new object. The object will be inserted below the existing one and will
get a new name "
first import of an eponymous object; example: "PLC_PRG" -> "PLC_PRG_1"
• Rename the new object. Do the same for all subsequent conflicts. The renaming
will be done as described above for "Rename the new object" will be done for the
current object and for all subsequent objects where the same conflict arises.
• Replace the existing object. The existing object will be removed and replaced by
the imported one.
• Replace the existing object. Do the same for all subsequent conflicts. The
replacement as described above for "Replace the existing object" will be done for
the current object and for all subsequent objects where the same conflict arises.
• Skip the new object. The object will not be imported.
• Skip the new object. Do the same for all subsequent conflicts. The current object
and all subsequent objects where the same conflict arises will not be imported.
Additional information:
This tab shows the following information read from the File header and Content
header of the PLCopen XML-file:
File header: Company name, Company URL, Product name, Product version, Product
release, Creation date/time, Content description
Content header: Name (project name), Version, Modification date/time, Organization,
Author, Language, Comment