Menu Commands sorted by Categories
354
DMS 4.1 EN 03/2011 TD29
The following settings are valid for a source download, that is transferring the project
file(s) to the PLC.
Destination device:
By default no device is predefined here. However you can select one from the selection
list which offers all programmable devices defined in the project. If a destination
device is defined here, you cannot perform a source download if you are currently
connected to another device.
Content:
Predefines the selection of project-belonging files to be stored in the archive file for
source download.
Project file only: only the
All files (project, libraries, device descriptions, etc.): Default
Timing:
Predefines when a source download will be done:
Implicitly at program download: The source download is executed at each program
download (command Online \ Download '
Prompt at program download: At each program download the user will be asked
whether also a source download should be done.
Implicitly at creating bootproject: The source download is executed at each boot
project creation (command Online \ Create boot application) without any user
interaction.
Only on demand: The source download has to be initiated by command Source
Download.