Function block l_smc_touchprobe (for ethercat), L-force | plc designer – Lenze PLC Designer PLC Designer (R3-1) User Manual
Page 30
![background image](/manuals/566301/30/background.png)
L-force | PLC Designer
Lenze Specific Functions
28
DMS 4.1 EN 03/2011 TD29
Function block L_SMC_TouchProbe (for EtherCAT)
Function library: L_SM3_DriveUtil.lib
This purpose of this block is to detect the position of the drive with a high degree of
accuracy via a fast input. Previously, the assignment and feedback of measured values
took place by means of SDO access. If the drive is controlled via an EtherCAT fieldbus, it
is possible to transfer these data as part of the cyclical process data. The advantage is
substantially faster transfer of the data from and to the drive. In order to be able to use
this, a corresponding mapping that contains these data as an item of process data
must be selected.
Inputs (VAR_IN)
Designator / Data type
Info / Setting options
Execute / BOOL
When a new positive edge is set, a new measuring is started. All outputs of
the block are reset to the initial values.
WindowsOnly / BOOL
Activation of window evaluation: All measured values outside the defined
window are suppressed.
FirstWindowsPosition /
LREAL
Lower limit of the window in SoftMotion units [SM units]
LastWindowPosition /
LREAL
Upper limit of window in SoftMotion units [SM units]
TriggerInput /
L_SMC_Trigger_REF
See following description
Axis / AXIS_REF
Selection of the drive