Toggle Bit

Toggles (turn off/on) an internal tag or PLC tag coil/bit

Copy Tag B to Tag A

Copies a value residing in the Tag B register to the target Tag
A register

Swap Tag A and Tag B

Swaps (exchanges) the values residing in the Tag A register
and the Tag B register

Print Data

Prints the displayed screen (to a connected serial printer)

Set RTC

Change a set value (i.e. year, month, day, etc) of the internal
real-time clock of the controller

Copy Tag to LED

Controls the Function Key LEDS

Copy HMI Block to HMI/PLC
Block

Copies the values in a block of continuous registers
beginning with the Tag B register to the block of registers
designated with the Tag A register

Copy HMI/PLC Block to HMI
Block

Copies the values in a block of continuous registers
beginning with the Tag B register to the block of registers
designated with the Tag A register

Copy RTC to PLC Block

Copies the real-time clock (RTC) data in the HMC to a
consecutive set of 16-bit registers (using BCD format) in the
PLC beginning with the target tag

USB Data Log Upload

Copies (uploads) a series of data registers into a USB Flash
Drive

Wait While

Any tasks in the list that are after this task will not be
executed until this condition is true

Delay

Any tasks in the list that are after this task will not be
executed until the delay time has expired

Key Specific Task:

Tasks that can only be executed using a membrane function
key or the Advanced Bit or Word button on screen

Clear Data Entry Clears value displayed in Data Entry window of keypad

Cancel Data Entry Restores the original value in the Data Entry window of

keypad and discontinues entry

Accept Data Entry Writes the value displayed in Data Entry window of keypad

to target register