Maple Systems MAPware-7000 User Manual
Page 187
![background image](/manuals/358884/187/background.png)
MAPware-7000 Programming Manual
187
1010-1040, Rev. 02
Trend Properties Options
Appearance section – these attributes determine the general look of the trend.
Background Color - determines the fill or background color of the trend graph. Click on
the
button to display the color palette and select a color.
Data Type – options are:
Data Type
Range
Target Address
(2 bytes)
Target Address
(4 bytes)
Unsigned
0 to 65535
0 to 4294967295
Signed
-32768 to 32767
-2147483648 to
2147483647
Hexadecimal
0000 to FFFF
0000 to FFFFFFFF
BCD
1
0 to 9999
0 to 99999999
Floating Point
2
NA
Maximum of 9 digits
1- If the value in the monitored target register is not a valid BCD number, a dollar sign
‘$’ is displayed.
2- Floating Point format is based upon the IEEE 754 standard for 32-bit single precision
numbers. A maximum of nine digits is supported. Values are rounded to the
nearest decimal point (ex: if Format: Digits After Decimal Point is set to 1 digit, then
floating point number 1.52 would be displayed as 1.5 and 1.56 would be displayed
as 1.6) shows the current state displayed on the Multiple Bar Graphs for editing
Error Message Font Color – determines the color of any error messages that may appear
during the execution of the trend graph. Click on the
button to display the color
palette and select a color.
Font – used to configure the pixel size (WxH) of the error message. Options are 5x7 and
7x14 pixels. Note: error messages that do appear display along the bottom of the trend
graph.
Grid – option to display grid lines on the trend graph
Grid Color – determines the color of the grid lines. Click on the
button to display the
color palette and select a color.
Label – option to have a text label appear on the top of the trend.
o Label Font – determines the font type, size, etc.
Name- Type font used
Size- select font size
Bold- select ‘True’ to enable
Italic- select ‘True’ to enable
Underline- select ‘True’ to enable
o Label Text – enter the text to appear in the label.
o Label Text Color – determines the text color of the label. Click on the
button
to display the color palette and select a color.
Language – highlight the language that must be selected to display the entered text.
Span – options are Time (sec) or Tag Selected. Select Time (sec) to configure a pre-
defined length of time (in seconds) for the values plotted on the trend graph. Use Tag
Selected to configure a PLC target address continuously read by the HMC to determine
the length of time used by the trend graph.