Maple Systems MAPware-7000 User Manual

Page 163

background image

MAPware-7000 Programming Manual

163

1010-1040, Rev. 02

Data Type

Range

Target Address
(2 bytes)

Target Address
(4 bytes)

Unsigned

0 to 65535

0 to 4294967295

Signed

-32768 to 32767

-2147483648 to
2147483647

Hexadecimal

0000 to FFFF

0000 to FFFFFFFF

BCD

1

0 to 9999

0 to 99999999

Binary

16 bits

16 bits

Floating Point

2

NA

Maximum of 9 digits

ASCII

3

Max length is 255
chars

Max length is 255
chars

ASCII Numeric

4

Max length is 10
chars

Max length is 10
chars

1- If the value in the monitored target register is not a valid BCD number, a dollar sign ‘$’ is

displayed.

2- Floating Point format is based upon the IEEE 754 standard for 32-bit single precision

numbers. A maximum of nine digits is supported. Values are rounded to the nearest decimal
point (ex: if Format: Digits after Decimal Point is set to 1 digit, then floating point number
1.52 would be displayed as 1.5 and 1.56 would be displayed as 1.6).

3- ASCII format interprets the data value in each 16-bit register as two ASCII printable

characters. Hex values 0-9 are displayed as numbers 0-9, 0A-1F is displayed as small case
decimal numbers, 20-FF is printable ASCII characters. The HMC reads consecutive registers
according to the Length field (ex: if Length=10, then HMC will read five consecutive registers,
starting with the designated Tag Address).

4- ASCII Numeric is the same as ASCII except that all non-printable values are displayed as

zeroes.

o Enable Control Bit – if enabled, the HMC monitors the selected bit tag address.

‘0’ prevents a new entry, ‘1’ allows normal editing by the operator.

o Hide Data – if enabled, data will be represented with asterisks ‘***’. This

feature used for security password entry.

o Keypad (List Pd) – selects using a popup keypad (Yes) or use a keypad on located

on the same screen (No)

o Maximum/Minimum Value (List Pe) – select the limits that the operator enters

as a valid number

o Screen Name/Number (List Pd) – determines which popup keypad to use
o Tag Address (List Qa) – this is the address of target register that is monitored
o Tag Name (List Qb) – this is the name given to the tagged register in the Tag

Database.

Design (List S) – identifies object

Layout (List T) – coordinates (i.e. size and position) for the object

Operation – use this feature to perform a mathematical calculation on the object data.

o First Operation – this is the first mathematical operation performed on the data

object. Options are NOP (no operation), addition (+), subtraction (-),
multiplication (*), and division (/).