beautypg.com

5motor control (mctrl) – Lenze 8400 motec User Manual

Page 85

background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

85

5

Motor control (MCTRL)

5.2

Motor selection/Motor data

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Other motor data
Click the Other motor data... button and go to the Other motor data dialog box including the motor

equivalent circuit:

• Generally, a synchronous motor without speed feedback can also be operated with the

V/f

characteristic control (VFCplus)

control mode. The parameters for this control mode (e.g. V/f

base frequency) thus also have an according influence on synchronous motors.

Parameter

Info

ASM

PSM

C00084

Motor stator resistance

C00085

Motor stator leakage inductance

C00095

Motor magnetising current

C00092

Motor magnetising inductance

C00015

VFC: V/f base frequency

C00021

Slip compensation

C00075

Vp current controller

C00076

Ti current controller

C00273

Moment of inertia

C00016

VFC: Vmin boost

C00070/3

SLPSM: Vp speed controller

C00071/3

SLPSM: Ti speed controller

C00011

Appl.: Reference speed

C00022

Imax in motor mode

C00982

VFC-ECO: Voltage reduction ramp

C00073

Vp Imax controller