6 pre-assignment of the application, 1 input connections, Pre-assignment of the application – Lenze 8400 motec User Manual
Page 254: Input connections, 7technology applications, 4 ta "switch-off positioning" 254
7
Technology applications
7.4
TA "Switch-off positioning"
254
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.4.6
Pre-assignment of the application
7.4.6.1
Input connections
Control modes 10 / 12 / 14 / 16 for control via terminals
Config.
parameter
Identifier
Control mode
10: Terminals 0
see chapter
12: Terminals 2
14: Terminals 11
16: Terminals 16
nMainSetValue_a
AU
AU
AU
AU
nTorqueMotLim_a
nTorqueGenLim_a
Key-operated switch: Max. speed
Poti P1
Poti P1
Poti P1
Poti P1
Network(MCI/CAN)_wDriveControl
0x0009
0x0009
0x0009
0x0009
nPIDVpAdapt_a
100 %
100 %
100 %
100 %
nPIDActValue_a
-
-
-
-
nPIDInfluence_a
100 %
100 %
100 %
100 %
nPIDSetValue_a
-
-
-
-
Reserved
-
-
-
-
: wLdVal
-
-
-
-
: wCmpVal
-
-
-
-
: nIn1_a
-
-
-
-
: nIn2_a
-
-
-
-
: wParIndex
-
-
-
-
: wParSubindex
-
-
-
-
: wInHWord
-
-
-
-
: wInLWord
-
-
-
-
Reserved
-
-
-
-
bCInh
-
-
-
-
bFailReset
DI3
RFR
RFR
RFR
bSetQuickstop
-
-
-
-
bSetDCBrake
-
-
-
-
bSetSpeedCcw
DI4
-
-
-
bJogSpeed1
:
bJog1Out
bJog1Out
bJog1Out
:
bJog1Out
bJogSpeed2
:
bJog2Out
bJog2Out
bJog2Out
:
bJog2Out
bMPotUp
-
-
-
-
bMPotDown
-
-
-
-
bMPotInAct
-
-
-
-
bMPotEnable
-
-
-
-
bRFG_0
:
bRfgOut
bRfgOut
bRfgOut
:
bRfgOut
bSetError1
-
-
-
-
bSetError2
-
-
-
-
bPIDInfluenceRamp
TRUE
TRUE
TRUE
TRUE
bPIDIOff
-
-
-
-
bRLQCw
TRUE
DI3
DI3
DI3
bRLQCcw
-
DI4
DI4
DI4
bBrkRelease
DI5
DI5
DI5
DI5
: bClkUp
-
-
-
-
: bClkDown
-
-
-
-
: bLoad
-
-
-
-
: bIn
-
-
-
-