C00586 | resp. to encoder open circuit, C00594 | resp. to control word error, C00597 | resp. to lp1 motor phase fault – Lenze 8400 motec User Manual
Page 385: C00586, Is activated, C00597, A mo, C00594/2, 11 parameter reference

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
385
11
Parameter reference
11.2
Parameter list | C00586
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00586
C00594
C00597
Parameter | Name:
C00586 | Resp. to encoder open circuit
Data type: UNSIGNED_8
Index: 23989
d
= 5DB5
h
From version 02.00.00
Response to encoder feedback system failure or encoder feedback system track failure due to open circuit
Note:
Despite the encoder error, monitoring is not activated if the setpoint is lower than or equals 40 Hz.
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
4 WarningLocked
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00594 | Resp. to control word error
Data type: UNSIGNED_8
Index: 23981
d
= 5DAD
h
Configuration of device control monitoring
Selection list
0 No Reaction
1 Fault
2 Trouble
4 WarningLocked
Subcodes
Lenze setting
Info
C00594/1
0: No Reaction
Response if error bit 14 in the CAN control word is set.
C00594/2
1: Fault
Response if error bit 14 in the MCI control word is set.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00597 | Resp. to LP1 motor phase fault
Data type: UNSIGNED_8
Index: 23978
d
= 5DAA
h
Response to motor phase failure
• Online testing includes the monitoring of the three motor phases during operation (motor rotates).
• Static testing means testing before the holding brake is released.
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
4 WarningLocked
Read access Write access CINH PLC STOP No transfer COM MOT