5motor control (mctrl) – Lenze 8400 motec User Manual
Page 83
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
83
5
Motor control (MCTRL)
5.2
Motor selection/Motor data
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Motor data
In the parameterisation dialog, the data of the motor nameplate for the selected motor are
displayed under "Motor data".
Actual values
When an online connection to the controller has been established, the following actual values are
displayed in the parameterisation dialog under "Actual values":
Note!
Sensorless vector control in particular requires the motor data parameters to be set. The
motor data comprise the data of the motor nameplate and the data of the motor
equivalent circuit.
If the motor has been selected via the motor catalogue of the »Engineer« or the motor
data have been adapted offline using the »Engineer«, all motor data must then be
copied to the controller and saved power-failure-proof to the memory module (device
command:
) when an online connection has been established.
Parameter
Info
Rated motor power
Rated motor speed
Rated motor current
Rated motor frequency
Rated motor voltage
Motor cos ϕ
Parameter
Info
Actual speed value
Motor voltage
DC-bus voltage
Motor current
Thermal motor load (I2xt)
Highlighted in grey = display parameter