C00181 | time settings, C00182 | s-ramp time pt1, C00199 | device name – Lenze 8400 motec User Manual
Page 365: C00200 | firmware product type, C00201 | firmware compile date, C00200, C00199/1, Time set in, C00181/1, C00182
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
365
11
Parameter reference
11.2
Parameter list | C00181
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00181
C00182
C00199
C00200
C00201
Parameter | Name:
C00181 | Time settings
Data type: UNSIGNED_16
Index: 24394
d
= 5F4A
h
From version 04.00.00
Time for device search function (optical location)
Setting range
(min. value | unit | max. value)
0
s
6000
Subcodes
Lenze setting
Info
C00181/1
5 s
Time - device search function
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00182 | S-ramp time PT1
Data type: INTEGER_16
Index: 24393
d
= 5F49
h
FB
: PT1 S-ramp time for the main setpoint ramp function generator
• Only effective with activated ramp rounding (
= "1").
Setting range
(min. value | unit | max. value)
Lenze setting
0.01
s
50.00 20.00 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00199 | Device name
Data type: VISIBLE_STRING
Index: 24376
d
= 5F38
h
From version 04.00.00
Parameters for storing decription data for the controller
Subcodes
Lenze setting
Info
C00199/1
0
Read access Write access CINH PLC-STOP No transfer COM MOT
Character length: 32
Parameter | Name:
C00200 | Firmware product type
Data type: VISIBLE_STRING
Index: 24375
d
= 5F37
h
Display of the firmware product type
Read access Write access CINH PLC-STOP No transfer COM MOT
Character length: 19
Parameter | Name:
C00201 | Firmware compile date
Data type: VISIBLE_STRING
Index: 24374
d
= 5F36
h
Display of the firmware compilation date
Read access Write access CINH PLC-STOP No transfer COM MOT
Character length: 22