beautypg.com

2 deactivate motor potentiometer, 12 function library – Lenze 8400 motec User Manual

Page 442

background image

12

Function library

12.1

L_MPot_1

442

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.1.2

Deactivate motor potentiometer

When the motor potentiometer is deactivated by setting bInAct to TRUE, the nOut_a output signal

responds according to the function selected in

C00804

.

[12-2] Example: Deactivation of the motor potentiometer if

C00804

= "1: Deceleration to 0"

 When the motor potentiometer is deactivated, nOut_a is reduced to 0 % with the deceleration time wTif.

 If it is activated again, nOut_a is increased again to nLowLimit with the acceleration time wTir.

nOut_a

t

t

TRUE

FALSE

bUp

t

TRUE

FALSE

bDown

nHighLimit

nLowLimit

0

wTir

wTif

wTir

t

TRUE

FALSE

bInAct

wTif

wTif

0

1