1 terminals 0, 2 terminals 2, Terminals 0 – Lenze 8400 motec User Manual
Page 215: Terminals 2, 7technology applications
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
215
7
Technology applications
7.2
TA "Actuating drive speed"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.2.3.1
Terminals 0
7.2.3.2
Terminals 2
Connection
Assignment
Connection
Assignment
DI1
LA_NCtrl.bJogSpeed1
RFR
LA_NCtrl.bFailReset
DI2
LA_NCtrl.bJogSpeed2
AU/AI
LA_NCtrl.nMainSetValue_a
10 V ≡ 100 % reference speed (
)
DI3
LA_NCtrl.bSetDCBrake
DI4
LA_NCtrl.bSetSpeedCcw
NO, COM
LA_NCtrl.bDriveFail
DI5
LA_NCtrl.bBrkRelease
DO1
LA_NCtrl.bDriveReady
X3/X4
NO
COM
AR
AU/AI
GND
RFR
DI1
DI2
DI3
DI4
DI5
DO1
24O
GND
Speed setpoint
Enable controller / reset error message
Selection of fixed setpoint 1/3
Selection of fixed setpoint 2/3
Manual DC-injection braking (DCB)
Direction of rotation CCw
Manual release of the holding brake
DriveFail
DriveReady
Connection
Assignment
Connection
Assignment
DI1
LA_NCtrl.bJogSpeed1
RFR
LA_NCtrl.bFailReset
DI2
LA_NCtrl.bJogSpeed2
AU/AI
LA_NCtrl.nMainSetValue_a
10 V ≡ 100 % reference speed (
)
DI3
LA_NCtrl.bSetQuickstop
DI4
LA_NCtrl.bSetSpeedCcw
NO, COM
LA_NCtrl.bDriveFail
DI5
LA_NCtrl.bBrkRelease
DO1
LA_NCtrl.bDriveReady
NO
COM
AR
AU/AI
GND
RFR
DI1
DI2
DI3
DI4
DI5
DO1
24O
GND
X3/X4
Speed setpoint
Enable controller / reset error message
Selection of fixed setpoint 1/3
Selection of fixed setpoint 2/3
Quick stop
Direction of rotation CCw
Manual release of the holding brake
DriveFail
DriveReady