9diagnostics & error management, 8 error messages of the operating system – Lenze 8400 motec User Manual
Page 303
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
303
9
Diagnostics & error management
9.8
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x3668
13928
nt04: COM fault 4
Fault
-
0x3669
13929
nt05: COM fault 5
Fault
-
0x3669
13929
nt08: COM fault 8
Fault
-
0x360e
13838
nt14: COM fault 14
Fault
0x3666
13926
nt15: COM fault 15
Fault
0x3665
13925
nt16: COM fault 16
Fault
0x1710
5904
oC1: Power section - short circuit
Fault
-
0x2000
0x1711
5905
oC2: Power section - earth fault
Fault
-
0x2000
0x1332
4914
oC5: Ixt overload
WarningLocked
0x2000
0x1769
5993
oC6: I2xt motor overload
WarningLocked
0x2000
0x1707
5895
oC7: Motor overcurrent
Fault
-
0x2000
0x1334
4916
oC9: Ixt overload - shutdown limit
Fault
-
0x2000
0x1747
5959
oC11: Current clamp for too long (>1 sec)
Fault
-
0xF000
0x1741
5953
OC12: I2xt brake resistor overload
Fault
-
0xF000
0x1301
4865
oH1: Heatsink overtemperature
Fault
-
0x4000
0x130f
4879
oH3: Motor temperature triggered
Fault
0x4000
0x1300
4864
oH4: Heatsink temp. > shutdown temp. -5°C
No Reaction
0x4000
0x1720
5920
oS1: Maximum speed limit reached
No Reaction
0x8400
0x1721
5921
oS2: Max. motor speed
Fault
-
0x8400
0x175d
5981
ot2: Speed controller limitation
No Reaction
0xF000
0x170e
5902
OU: DC bus overvoltage
Trouble
-
0x3100
0x2c01
11265
PS01: No memory module
Fault
-
0x6300
0x2c02
11266
PS02: Invalid par. set
Fault
-
0x6300
0x2c03
11267
PS03: Invalid device par. set
Fault
-
0x6300
0x2c04
11268
PS04: Par. set device incompatible
Fault
-
0x6300
0x2c1f
11295
PS31: Ident. error
Fault
-
0x6300
0x17c8
6088
Sd10: Speed limit for feedback system 12
Fault
0x7300
0x17cd
6093
Sd3: Feedback system open circuit
Fault
0x7300
0x1b03
6915
Smr1: Module internal watchdog or trap
Fault
-
0x6100
0x1b04
6916
Smr2: Module offline - no status or PDOs
Fault
-
0x6100
0x1b05
6917
Smr3: Module timeout - one or more of PDOs timeout Fault
-
0x6100
0x1b06
6918
Smr4: SDO access failure
Fault
-
0x6100
0x0b02
2818
Su02: One mains phase is missing
WarningLocked
0x3000
0x6401
25601
US01: User error 1
Fault
0x6200
0x6501
25857
US02: User error 2
Fault
0x6200
Error number
Error message
Response
(Lenze setting)
can be set in
CAN Emergency
Error Code
32 bits
16 bits
hex
16 bits
dec