beautypg.com

5 setting parameters (short overview), Setting parameters (short overview), 7technology applications – Lenze 8400 motec User Manual

Page 253

background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

253

7

Technology applications

7.4

TA "Switch-off positioning"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.4.5

Setting parameters (short overview)

Parameter

Info

Lenze setting

Value Unit

C00011

Appl.: Reference speed

1500 rpm

C00012

Accel. time - main setpoint

2.0 s

C00013

Decel. time - main setpoint

2.0 s

C00105

Decel. time - quick stop

5.0 s

C00039/1

Fixed setpoint 1

40.0 %

C00039/2

Fixed setpoint 2

60.0 %

C00039/3

Fixed setpoint 3

80.0 %

C00488/1

L_JogCtrlExtension_1: InputSens.SlowDown1

0: Level

C00488/2

L_JogCtrlExtension_1: InputSens.Stop1

0: Level

C00488/3

L_JogCtrlExtension_1: InputSens.SlowDown2

0: Level

C00488/4

L_JogCtrlExtension_1: InputSens.Stop2

0: Level

C00488/5

L_JogCtrlExtension_1: InputSens.SlowDown3

0: Level

C00488/6

L_JogCtrlExtension_1: InputSens.Stop3

0: Level

C00182

S-ramp time PT1

20.00 s

C00134

Ramp rounding - main setpoint

0: Off

C00632/1

L_NSet_1: Blocking speed 1 max

0.00 %

C00632/2

L_NSet_1: Blocking speed 2 max

0.00 %

C00632/3

L_NSet_1: Blocking speed 3 max

0.00 %

C00633/1

L_NSet_1: Blocking speed 1 min

0.00 %

C00633/2

L_NSet_1: Blocking speed 2 min

0.00 %

C00633/3

L_NSet_1: Blocking speed 3 min

0.00 %