C00999 | slpsm: pll gain, C01000 | mctrl: status, C01082 | ls_writeparamlist: execute mode – Lenze 8400 motec User Manual
Page 410: C01082, 11 parameter reference
11
Parameter reference
11.2
Parameter list | C00999
410
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00999
C01000
C01082
Parameter | Name:
C00999 | SLPSM: PLL gain
Data type: INTEGER_16
Index: 23576
d
= 5C18
h
From version 03.00.00
Sensorless control for synchronous motor
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
1000 50 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01000 | MCTRL: Status
Data type: UNSIGNED_16
Index: 23575
d
= 5C17
h
From version 03.00.00
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 SL PSM: Mode
Bit 1 Reserved
Bit 2 Reserved
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C01082 | LS_WriteParamList: Execute Mode
Data type: UNSIGNED_8
Index: 23493
d
= 5BC5
h
: Selection of the activation method
Selection list
(Lenze setting printed in bold)
Info
0 by Execute
The writing of the parameter list is activated by a FALSE/
TRUE edge at the bExecute input.
1 by Input Select
The parameter list is written if a change is made at the
bSelectWriteValue_1 selection input and once when the
controller is initialised.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1