Commissioning
3.8
Control via field package ("key-operated switch operation")
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
How to reset the field package functionality using the »Engineer«
(e.g. after the Lenze setting has been loaded):
1. Show service codes in the »Engineer«:
• Execute the Extras Options command to open the Options dialog box.
• Go to the Service tab and activate the Show invisible parameters option.
2. Go to the All parameters tab and set the
service code to "1: On" to activate the field
package functionality.
The links of the digital inputs DI3, DI4 and DI5 via the configuration parameters
and
are evaluated independently of the field package functionality. Hence, make
sure to not assign more functions to these three digital inputs if the switchbox
functionality is used.
Note!
When loading the Lenze setting into the controller, reset the field package functionality
afterwards using the »Engineer« (see the following instructions).