beautypg.com

C00800 | l_mpot_1: upper limit, C00801 | l_mpot_1: lower limit, C00802 | l_mpot_1: acceleration time – Lenze 8400 motec User Manual

Page 396: Lue set in, C00800, C00802, C00801, C761/1, C761/2, C761/3

background image

11

Parameter reference

11.2

Parameter list | C00761

396

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00761

C00800

C00801

C00802

Parameter | Name:

C00761 | L_JogCtrlExtension_1: Digital connection list

Data type: UNSIGNED_16

Index: 23814

d

= 5D06

h

From version 05.00.00

Connection parameters for FB

L_JogCtrlExtension_1

• Selection of the binary output signals to be connected to the binary input signals

• The selection list contains all binary output signals which can be assigned to the binary inputs of the FB mapped

by the subcodes.

Selection list
See

selection list - digital signals

Subcodes

Lenze setting

Info

C00761/1

0: Not connected

L_JogCtrlExtension_1

: bInputSel1

C00761/2

10: LS_DigitalInput: bCInh

L_JogCtrlExtension_1

: bInputSel2

C00761/3

0: Not connected

L_JogCtrlExtension_1

: bSlowDown1

C00761/4

13: LS_DigitalInput: bIn3

L_JogCtrlExtension_1

: bStop1

C00761/5

14: LS_DigitalInput: bIn4

L_JogCtrlExtension_1

: bSlowDown2

C00761/6

11: LS_DigitalInput: bIn1

L_JogCtrlExtension_1

: blStop2

C00761/7

12: LS_DigitalInput: bIn2

L_JogCtrlExtension_1

: bSlowDown3

C00761/8

0: Not connected

L_JogCtrlExtension_1

: bStop3

C00761/9

0: Not connected

L_JogCtrlExtension_1

: bRfgIn

C00761/10

0: Not connected

L_JogCtrlExtension_1

: bJog1

C00761/11

0: Not connected

L_JogCtrlExtension_1

: bJog2

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00800 | L_MPot_1: Upper limit

Data type: INTEGER_16

Index: 23775

d

= 5CDF

h

The

L_MPot_1

FB: Upper limit of the motor potentiometer function

Setting range

(min. value | unit | max. value)

Lenze setting

-199.9

%

199.9 100.0 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00801 | L_MPot_1: Lower limit

Data type: INTEGER_16

Index: 23774

d

= 5CDE

h

The

L_MPot_1

FB: Lower limit of the motor potentiometer function

Setting range

(min. value | unit | max. value)

Lenze setting

-199.9

%

199.9 -100.0 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00802 | L_MPot_1: Acceleration time

Data type: UNSIGNED_16

Index: 23773

d

= 5CDD

h

The

L_MPot_1

FB: Acceleration time of the motor potentiometer function

Setting range

(min. value | unit | max. value)

Lenze setting

0.1

s

999.9 10.0 s

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10