C00800 | l_mpot_1: upper limit, C00801 | l_mpot_1: lower limit, C00802 | l_mpot_1: acceleration time – Lenze 8400 motec User Manual
Page 396: Lue set in, C00800, C00802, C00801, C761/1, C761/2, C761/3
11
Parameter reference
11.2
Parameter list | C00761
396
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00761
C00800
C00801
C00802
Parameter | Name:
C00761 | L_JogCtrlExtension_1: Digital connection list
Data type: UNSIGNED_16
Index: 23814
d
= 5D06
h
From version 05.00.00
Connection parameters for FB
• Selection of the binary output signals to be connected to the binary input signals
• The selection list contains all binary output signals which can be assigned to the binary inputs of the FB mapped
by the subcodes.
Selection list
See
selection list - digital signals
Subcodes
Lenze setting
Info
C00761/1
0: Not connected
: bInputSel1
C00761/2
10: LS_DigitalInput: bCInh
: bInputSel2
C00761/3
0: Not connected
: bSlowDown1
C00761/4
13: LS_DigitalInput: bIn3
: bStop1
C00761/5
14: LS_DigitalInput: bIn4
: bSlowDown2
C00761/6
11: LS_DigitalInput: bIn1
: blStop2
C00761/7
12: LS_DigitalInput: bIn2
: bSlowDown3
C00761/8
0: Not connected
: bStop3
C00761/9
0: Not connected
: bRfgIn
C00761/10
0: Not connected
: bJog1
C00761/11
0: Not connected
: bJog2
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00800 | L_MPot_1: Upper limit
Data type: INTEGER_16
Index: 23775
d
= 5CDF
h
FB: Upper limit of the motor potentiometer function
Setting range
(min. value | unit | max. value)
Lenze setting
-199.9
%
199.9 100.0 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00801 | L_MPot_1: Lower limit
Data type: INTEGER_16
Index: 23774
d
= 5CDE
h
FB: Lower limit of the motor potentiometer function
Setting range
(min. value | unit | max. value)
Lenze setting
-199.9
%
199.9 -100.0 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00802 | L_MPot_1: Acceleration time
Data type: UNSIGNED_16
Index: 23773
d
= 5CDD
h
FB: Acceleration time of the motor potentiometer function
Setting range
(min. value | unit | max. value)
Lenze setting
0.1
s
999.9 10.0 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10