14 ls_convert_2, Ls_convert_2, 12 function library – Lenze 8400 motec User Manual
Page 481
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
481
12
Function library
12.14
LS_Convert_2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.14
LS_Convert_2
This function extension is available from version 05.00.00!
This FB serves to execute various conversions/scalings.
• The SB is used in the "AC Drive Profile" application for converting the torque values received and
to be sent via bus (see AC Drive Profile
• The first path (In1 Out1) is used to convert the torque setpoint for the application.
• The second path (In2 Out2) is used to convert the actual torque value from the application
for the output on the bus.
• The SB can also be used for migrating an 8200 motec project into other applications.
Inputs
Outputs
Parameter
Identifier
Data type
Information/possible settings
In1
Input signal 1
In2
Input signal 2
Identifier
Data type
Value/meaning
Out1
Output signal 1
Out2
Output signal 2
Parameter
Possible settings
Info
-128
127 ACDrive: Torque scaling
Function selection
0 1 ==> 1 ==> 1
See subchapter "
"
1 1 Hz ==> % (C11) ==> 1 Hz
... ...
16 0.001 Nm ==> % (C57) ==> 0.001 Nm
17 ACDP ==> CAN ==> ACDP
For converting the AC Drive Profile
control word and status word
18 x C471_1 / C471_2
Parameterisable conversion
19 Act position 32bit ==> 16Bit
See description of FB L_Convert_1.
providing external encoder pulses