5motor control (mctrl) – Lenze 8400 motec User Manual
Page 168

5
Motor control (MCTRL)
5.12
Braking operation/brake energy management
168
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
How to set the "inverter motor brake" function for an oscillation-reduced operation:
For V/f characteristic open-loop control/closed-loop control (VFCplus):
• Set additive speed (
) to rated slip speed.
• Adapt the deceleration ramp so that the deceleration time is slightly below (10 ... 30 %)
the deceleration time that can be realised with the inverter motor brake.
How to set the "inverter motor brake" function for a maximum acceleration ramp:
For V/f characteristic open-loop control/closed-loop control (VFCplus):
• Set additive speed (
) to 1,5 ... 2,5-fold rated slip speed.
• Adapt the deceleration ramp so that the deceleration time is slightly below (10 ... 30 %)
the deceleration time that can be realised with the inverter motor brake.
For sensorless vector control (SLVC):
• Set additive speed (
) to 2 ... 4-fold rated slip speed.
• Adapt the deceleration ramp so that the deceleration time is slightly below (10 ... 30 %)
the deceleration time that can be realised with the inverter motor brake.