6 enable controller and test application, Enable controller and test application, 3commissioning – Lenze 8400 motec User Manual
Page 50

3
Commissioning
3.6
Commissioning of the "Switch-off positioning" technology application
50
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.6.5
Saving parameter settings safe against mains failure
The parameter set must be saved to the device safe against mains failure to prevent parameter
settings becoming lost due to mains switching.
•
Save parameter set.
3.6.6
Enable controller and test application
If the controller is in the "
1. Enable controller: Set terminal RFR to HIGH level.
2. Select the respective control signals via the digital inputs.
Stop!
Before stipulating a speed setpoint, check whether the brake in the form of a holding
brake on the motor shaft has been released!
Note!
If the controller is enabled and the "Inhibit at power-on" auto-start option is activated in
(Lenze setting) when the mains is connected, the controller remains in the
In order to change to the "
" status, the controller enable must first be
cancelled: Set terminal RFR to LOW level.
Note!
Observe the actual speed value (display in
) and the
at the
controller.