4
Device control (DCTRL)
4.1
Device commands (C00002/x)
68
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.1.11
Device search function
This function extension is only available from version 04.00.00!
In some applications where controllers are positioned in a spacious plant, it is often difficult to lo-
cate a device connected online for e.g. maintenance work. There is an established online connection
with the device but you do not know where the controller is located physically.
The
= "1: On / start" device command serves to carry out an "optical location":
• For the time set in
, the LED display at the front of the device flashes. Afterwards, the
function is turned off automatically.
• If the device command is executed again within the set time period, the duration is extended
accordingly.
• The setting
= "0: Off / ready" serves to abort or switch off the function.
• Adjustable time period: 0 ... 6000 s (Lenze setting: 5 s)
Tip!
The device search function can also be activated via the
toolbar icon.