1 main setpoint path, 2 jog setpoints, 3 setpoint inversion – Lenze 8400 motec User Manual
Page 445: 12 function library

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
445
12
Function library
12.2
L_NSet_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.2.1
Main setpoint path
• The signals in the main setpoint path are limited to a value range of ±32767.
• The signal at nNSet_a is first led via the JOG selection function.
• A selected JOG value switches the nNSet_a input inactive. Then, the subsequent signal
conditioning operates with the JOG value.
12.2.2
JOG setpoints
In addition to the direct main setpoint selection via the nNSet_a input, so-called JOG setpoints can
be preset in
.
• The JOG setpoints are binary-coded and can be called using the bJog1 and bJog8 selection
inputs:
• The number of selection inputs to be assigned depends on the number of JOG setpoints
required.
12.2.3
Setpoint inversion
The output signal of the JOG function is led via an inverter.
The sign of the setpoint changes if bNSetInv is set to TRUE.
Status (bit-coded)
• Bits that are not listed are
reserved for future extensions.
Bit 0 No blocking zone active
Bit 1 Blocking zone 1 active
Bit 2 Blocking zone 2 active
Bit 3 Blocking zone 3 active
Bit 4 Jog in blocking zone
Bit 5 MaxLimit active
Bit 6 MinLimit active
Parameter
Possible settings
Info
Selection inputs
Used main setpoint
bJog2
bJog1
FALSE
FALSE
nNset_a
FALSE
TRUE
TRUE
FALSE
TRUE
TRUE