C01353 | acdrive: setpoint scaling, C01354 | ls_convert, C01354/2 – Lenze 8400 motec User Manual
Page 417: C01353/1, C01353/2, 11 parameter reference

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
417
11
Parameter reference
11.2
Parameter list | C01353
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01353
C01354
Parameter | Name:
C01353 | ACDrive: Setpoint scaling
Data type: INTEGER_8
Index: 23222
d
= 5AB6
h
From version 05.00.00
Application "Speed actuating drive (AC Drive Profile)": Scaling of the speed and torque values
Setting range
(min. value | unit | max. value)
-128
127
Subcodes
Lenze setting
Info
C01353/1
0
ACDrive: Speed scaling
C01353/2
0
ACDrive: Torque scaling
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01354 | LS_Convert
Data type: UNSIGNED_8
Index: 23221
d
= 5AB5
h
From version 05.00.00
Selection list
0 1 ==> 1 ==> 1
1 1 Hz ==> % (C11) ==> 1 Hz
2 0.1 Hz ==> % (C11) ==> 0.1 Hz
3 0.01 Hz ==> % (C11) ==> 0.01 Hz
4 0.001 Hz ==> % (C11) ==> 0.001 Hz
5 1 Rpm ==> % (C11) ==> 1 Rpm
6 0.1 Rpm ==> % (C11) ==> 0.1 Rpm
7 0.01 Rpm ==> % (C11) ==> 0.01 Rpm
8 0.001 Rpm ==> % (C11) ==> 0.001
Rpm
9 1 A ==> % (C22) ==> 1 A
10 0.1 A ==> % (C22) ==> 0.1 A
11 0.01 A ==> % (C22) ==> 0.01 A
12 0.001 A ==> % (C22) ==> 0.001 A
13 1 Nm ==> % (C57) ==> 1 Nm
14 0.1 Nm ==> % (C57) ==> 0.1 Nm
15 0.01 Nm ==> % (C57) ==> 0.01 Nm
16 0.001 Nm ==> % (C57) ==> 0.001 Nm
17 ACDP ==> CAN ==> ACDP
18 x C471_1 / C471_2
19 Act position 32bit ==> 16Bit
Subcodes
Lenze setting
Info
C01354/1
0: 1 ==> 1 ==> 1
: Function
C01354/2
0: 1 ==> 1 ==> 1
: Function
C01354/3
0: 1 ==> 1 ==> 1
: Function
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1